The junction between bifold doors and the external brickwork involves DPC, cavity closers, thresholds, and drainage. Each one needs to be right.

Bifold and sliding door openings are now standard on rear extensions across Kent. A 3 to 4-metre-wide opening floods the room with light and connects the kitchen or living area to the garden. But the brickwork detail at the threshold, the head, and the jambs must be right, or water will find its way in.

The Threshold

The bottom of the opening is the most vulnerable point. The external ground level or patio must be at least 150mm below the DPC to comply with Approved Document C. With bifold doors, homeowners want a flush threshold for a seamless indoor-outdoor transition. The solution is a recessed drainage channel directly outside the threshold, with a grated cover. The channel falls to one end and connects to a gully or soakaway. The external paving can then be brought up close to the threshold without breaching the DPC.

Cavity Closers and DPC

At the jambs (sides of the opening), insulated cavity closers (typically Thermabate or equivalent) are fitted between the outer and inner leaves to close the cavity and maintain thermal performance. A vertical DPC is incorporated to prevent moisture tracking across the closer. At the head, a cavity tray with stop ends and weep holes directs any moisture in the cavity out through the wall face above the lintel.

Getting the Levels Right

The relationship between the internal finished floor level, the structural slab or oversite, the DPC, and the external paving must be coordinated before the brickwork starts. Changing levels after the walls are built is extremely expensive. See our extension build guide for the full sequence. View our extension services.

Frequently Asked Questions

Step risers are in constant contact with ground moisture and exposed to frost. Engineering bricks have water absorption below 7% and do not spall in freeze-thaw conditions, unlike standard facing bricks which absorb moisture and can crack within a few winters.
Indian sandstone is the most popular for domestic gardens (30 to 50 per m2). York stone is premium (80 to 150+ per m2). Limestone offers a contemporary look but check porosity ratings for external use.
25 to 30mm. This creates a shadow line that defines the step edge for safety, and sheds rainwater away from the mortar joint at the base of the riser.
150mm is the standard. Going higher than 175mm feels steep; lower than 100mm feels like a trip hazard. All risers in a flight must be the same height.
Building Regulations do not apply to garden steps in the same way as internal stairs. However, if the flight is more than 3 or 4 risers, or if elderly users are expected, a handrail is strongly recommended for safety.